Lighting

80-CRI Spectrum Beats a 97-Ra Daylight Reference in Test With Older Observers

A Fudan University study in Optics Express tuned LED spectra to the aging eye and measured color-discrimination gains that conventional color metrics do not predict.

Lena VossOctober 20, 20265 min read9 views
A multichannel LED module casts diverging warm and cool light across a tabletop of colored sorting caps in a dim room.

A study published October 13 in Optics Express reports that a custom-mixed LED spectrum rated only 80 CRI helped people in their 70s and 80s sort colors more accurately than a simulated daylight reference rated 97. The work comes from Fudan University in Shanghai, with two Opple Lighting employees among its eight authors, and it suggests that the color metrics specifiers rely on may not describe what aging eyes actually see.

The problem with a fixed observer

As the eye's lens yellows with age it filters out short-wavelength light, changing how colors are perceived. Ra and TM-30, the two color metrics specifiers actually use, are calculated with a fixed standard observer that makes no allowance for lens aging, even though the CIE's own 2006 physiological model includes an age parameter.

Two new metrics and a screen of 11,541 spectra

The team modeled the color response of aging eyes and derived two metrics. One estimates how much of the color discrimination an older viewer has lost a given spectrum can recover. The other measures color fidelity against the perception of a 32-year-old. The researchers then screened 11,541 candidate spectra produced by a 16-channel LED luminaire, all at 5000 K and all with Ra of at least 80.

Two candidates were carried forward and tested against a simulated D50 daylight reference with an Ra of 97. P1 prioritized color discrimination at Ra 80; P2 balanced discrimination and fidelity at Ra 90. When the authors re-ranked every candidate using the conventional standard observer, P1 lost its top position, a sign that the spec-sheet favorite and the aging eye's favorite can be different lights.

Results from 34 older participants

Participants aged 70 and older, with a mean age of 81.7, sorted colored caps from the Farnsworth-Munsell 100 Hue test in a viewing booth at 300 lux. Mean error scores fell from 79.2 under the daylight reference to 62.4 under P1 and 65.0 under P2, and both reductions were statistically significant. Color discrimination improved for 26 of 34 participants (76.5%) under P1 and for 22 of 34 (64.7%) under P2. The difference between the two optimized spectra was not significant.

Asked whether fruits and vegetables looked natural, 28 participants said yes under P1, against 26 under both the reference and P2. The authors note that a two-person difference proves little, but it hints that P1's lower Ra carried no penalty in perceived naturalness.

Limitations and disclosures

  • The sample was small.
  • People with advanced cataracts, glaucoma or macular degeneration were excluded, which removes many of the residents a memory-care designer lights for.
  • Chromaticity between the reference and test lights was not perfectly matched.
  • The naturalness question was a simple yes or no.
  • The authors warn against reading 300 lux as a recommendation.

Opple financially supported the study, according to the paper's disclosures. The paper names no product, but a news release distributed through Optica, the journal's publisher, says Opple is working to translate the findings into lighting products. That makes the effort early product development as much as academic research. The underlying data is available only on request, which puts weight on independent replication.

Where the evidence meets specifications

The method requires at least four independently controlled LED channels. Multichannel color-mixing fixtures rarely appear in a care-facility bid, and most products sold as tunable in healthcare and senior living adjust color temperature across two channels, which would not reproduce these spectra. That product-side gap is a reading of the market rather than a claim in the paper.

For lighting people working in senior living and healthcare, the study poses a pointed question. The industry's color metrics make no allowance for aging eyes, and a growing share of building occupants are well past middle age. If a tuned spectrum can help a resident read a medication label or judge whether food has spoiled, the argument shifts to how quickly that evidence reaches specifications and product lines, and whose products get there first.